Ag T.S.S.


Autoclave Steam Sterilizer 230l
 
Autoclave Steam Sterilizer 230l

General product information

Our Autoclave sterilizer 230L is brand new offers the latest in sterilization technological advances at affordable cost.


Standard Features:

Secure Touch Touch Screen Controller

Front loading compact autoclave

230 liters

5 Programs

Virtual Printer

New Swift lock rapid access safety closure

Over temperature water cut out

Thermocouple entry port

Low Water Alarm on Internal Water Tank

Automatic timed air purge system

Pressure gauge

Vent valve

Stainless Steel Pressure Vessel.

Safety Testing

On Screen Graph display

Heaters in chamber

Printer (optional)
Control system:

Touch screen version of the Tried and Tested Secure2 controller

Audible warnings End of Cycle, Water Level, Faults etc

Easy Fingertip Operation even when wearing Lab Gloves

Selectable security operating levels with access PIN codes

Built-in provision for mandatory Safety valve tests etc

Internal and External plus 2 - colour printer options

Easy selection of program by Name and Settings

Onscreen chart graph display of running cycle

Easy Muting for audible Cycle warnings

Audible confirmation of key presses

Continuous Onscreen Display of Program Info, Times, Temperatures, Pressure, Cycle stage, Cycle Counter etc

New Virtual Printer Stores cycle details (1-2 months typical usage stored) in Printout format for easy download to PC laptop or external printer

Internal Fault Detection with automatic fault diagnosis and 3 fault memories for easy servicing

Simple to use Controls set out on the large 5.7 illuminated display with menus for all operations

Optional Communications including Ethernet, and USB connections


Safety Features:

Cooling locks: (in accordance with H.S.E. PM73) preventing opening of autoclave above 80C. (for fluid & discard cycles

Audible & Visual Alarms: for Cycle Fault - Cycle Interruption - Sterilize Failure - Water Low - Door Unlocked

Door Seal: Self Energising / Service independent

Door: The door release is interlocked by both temperature and pressure to ensure all residual pressure has completely and effectively vented to atmosphere before the doors can be opened. The door will retain its positions in the event of failure of any service. The door is thermally insulated to prevent the surface temperature presenting a hazard to operators. The surface temperature will not exceed IEC 61010 requirements. A cycle cannot start until the door is closed and locked. Steam cannot be applied to the chamber unless the door is closed and locked.

Interlocks: Safety interlocks are provided, and are achieved by hardware, separate from and additional to the control system. All interlocks are configured to fail-safe and to provide a signal to the control system to indicate that normal operation has been prevented, and to terminate the current cycle. The interlock system is designed so that its function can be tested during routine maintenance. Safety related interlocks are either hard wired or piped. The following safety interlocks are provided: If the door is not closed, the steam supply to the chamber will be isolated If the pressure in the chamber exceeds 0.15 bar the door will remain locked.