Autoclave Steam Sterilizer 330l
Autoclave Steam Sterilizer 330l

General product information
Our Autoclave sterilizer 330L is brand new offers the latest in sterilization technological advances at affordable costStandard Features:
Touch Screen Controller
Capacity: 330L
Multi Program
Pre-Vacuum
Negative & Positive Pulsing
Low Water Alarm on Integral Steam Generator
Vacuum Drying
Swiftlock rapid access safety closure
Over temperature water cut out on Integral Steam Generator
Thermocouple entry port
Pressure gauge
Stainless Steel Pressure Vessel.
Safety Valve Testing
Leak Test
Cool Lock Protection (fluid Cycles)
Full Colour Touch Screen
Data Archiving
5 Selectable security operating levels with Password Protected Security
Easy Fingertip Operation even when wearing Lab Gloves
Easy selection of program by Name and Settings
Audible confirmation of key presses
Simple Cycle Selection
RS232 Interface / Port - Allowing connection to other peripheral devices such as a printer
Operator Interface
Built-in provision for mandatory Safety valve tests etc
Enables continual monitoring
Audible warnings of Faults
Onscreen Display of Program Info, Times, Temperatures, Pressure, Cycle stage, Cycle Counter etc
Internal Fault Detection with automatic fault diagnosis and complete fault history for easy servicing
Simple to use Controls set out on the large illuminated Touch Screen display with menus for all operations
Optional Communications including Ethernet and RS232
This control system is an advance in sterilization control technology, bringing together years of unrivalled experience, to produce a user friendly, fully automatic control system, to meet and exceed the expectations of even the most demanding laboratories and centres of sterilization.
The controller consists of a wipe clean touch screen based on an industrial PLC controller, combined with a number of analogue and digital input/output modules.
The controller software has been developed for the precision control of autoclaves.
The code is split into well-defined blocks, each of which performs a specific function and has been written in high level language to allow maximum clarity.
Cooling locks
(in accordance with H.S.E. PM73) preventing opening of autoclave above 80C. (for fluid & discard cycles)
Audible & Visual Alarms
for Cycle Fault - Cycle Interruption - Sterilize Failure - Water Low - Door Unlocked
Door Seal
Self Energising / Service independent
Door
The door release is interlocked by both temperature and pressure to ensure all residual pressure has completely and effectively vented to atmosphere before the doors can be opened. The door will retain its positions in the event of failure of any service. The door is thermally insulated to prevent the surface temperature presenting a hazard to operators. The surface temperature will not exceed IEC 61010 requirements. A cycle cannot start until the door is closed and locked. Steam cannot be applied to the chamber unless the door is closed and locked.
Interlocks
Safety interlocks are provided, and are achieved by hardware, separate from and additional to the control system. All interlocks are configured to fail-safe and to provide a signal to the control system to indicate that normal operation has been prevented, and to terminate the current cycle. The interlock system is designed so that its function can be tested during routine maintenance. Safety related interlocks are either hard wired or piped. The following safety interlocks are provided: If the door is not closed, the steam supply to the chamber will be isolated If the pressure in the chamber exceeds 0.15 bar the door will remain locked